Skip to Content

Home›Gateway›GateBerry

GateBerry: industrial gateway with Raspberry Pi and Linux

A DIN-rail edge gateway that connects your RS-485 field devices to your TCP/IP network and the cloud. Native Linux, Node-RED and Python, with a UPS for safe shutdowns.

  • Modbus RTU to Modbus TCP and MQTT with no extra hardware and no proprietary stack.
  • Gigabit Ethernet, RS-485 and 4 USB, plus LoRa, 4G, CAN or GPS in FLEX.
  • UPS built in: a clean shutdown when the power fails.
GateBerry industrial gateway with Raspberry Pi for DIN rail

From the field bus to your network

One device between your RS-485 devices and your IT systems.

What a GateBerry does

Collects data from Modbus RTU devices on RS-485: meters, drives, sensors.

Translates it to Modbus TCP, MQTT or your own protocol with Node-RED or Python on Linux.

Sends it to your SCADA, database or cloud over Ethernet, 4G or LoRa.

GateBerry Raspberry Pi and Linux gateway
  • Gigabit EthernetFast link to the plant or office network.
  • RS-485Modbus RTU and other field buses out of the box.
  • UPSSafe shutdown and protected data on power loss.
  • Linux, Node-RED, PythonYour gateway logic, with the tools your team knows.
  • microSD card8 GB TLC microSD card with Linux preinstalled.
  • 0 to 60 °COperating temperature, non-condensing humidity 10 to 90%.

CORE or FLEX

The same gateway in two ways of buying it.

Ready to ship

GateBerry CORE

  • Gigabit Ethernet, RS-485, 4 USB and UPS.
  • 2 GB RAM and Linux installed.

Configured to order

GateBerry FLEX

  • Up to 16 GB of RAM.
  • Add LoRa, 4G, CAN, GPS or M-Bus.

Not sure which model? Compare every model by inputs, outputs and communications.

What you can build with it

Real projects with the problem, the solution and the hardware they use.

GateBerry gateway

Energy

Energy meters to the cloud

Read Modbus RTU meters and publish the data over MQTT.

GateBerry gateway

Machines

Machine data to SCADA

Bridge RS-485 machines to a Modbus TCP SCADA without changing them.

GateBerry gateway

Remote sites

Remote sites over 4G or LoRa

Collect data where there is no cable, with the FLEX communication boards.

Learn and start

  • Modbus TCP and RTU

    Python and Node-RED examples on Raspberry-based devices.

    Modbus guide
  • Node-RED SCADA course

    Build dashboards and data flows with Node-RED.

    Start the course
  • RS-485 troubleshooting

    6 checks when a Modbus RTU bus fails.

    RS-485 checks
  • FAQ

    Power supply, communications and choosing a model.

    Read the FAQ

Questions about GateBerry

Can it convert Modbus RTU to Modbus TCP?

Yes. GateBerry bridges Modbus RTU devices on RS-485 to your TCP/IP network, with Node-RED or Python on Linux.

Does it need proprietary software?

No. It runs Linux, Node-RED and Python.

What happens if the power fails?

The built-in UPS keeps it running long enough to shut down cleanly and protect the data.

What is the difference between CORE and FLEX?

CORE is ready to ship with 2 GB of RAM. FLEX is configured to order with up to 16 GB and LoRa, 4G, CAN, GPS or M-Bus.

Talk to an engineer

Tell us what the system must do and which signals it has. An Industrial Shields engineer will answer with the right model and the next steps.

Thank you. We have received your message and an engineer will contact you.