Ardbox Analog I/Os

Ardbox Analog Pinout


General I/Os features






Ardbox Analog I/O pinout







Switch configuration




6. DE-RS485 If this switch is ON, the A0.2-Q0.2 switch must be set to OFF. Being in ON mode
it enables DE for the RS-485.

5. A0.2-Q0.2 – If this switch is ON, the DE-RS485 switch must be set to OFF. Being in ON mode
it enables the outputs A0.2-Q0.2.

4. RE-RS485 – If this switch is ON, the A0.1-Q0.1 switch must be set to OFF. Being in ON mode
it enables EE for the RS-485.

3. A0.1-Q0.1 – If this switch is ON, the RE-RS485 switch must be set to OFF. Being in ON mode
it enables the outputs A0.1-Q0.1.

2. SDA-D2/I0.0 – Choosing between SDA (I2C) and I0.0. If this switch is ON, the I0.0 input will
be enabled and the SDA will be disabled. If this switch is OFF, the SDA will be now available
and I0.0 disabled.

1. SCL-D3/Q0.6 – Choosing between SCL (I2C) and Q0.6. If this switch is ON, the Q0.6 input will
be enabled and the SCL will be disabled. If this switch is OFF, the SCL will be now available and
Q0.6 disabled.