Industrial Pull UP I2C connection
Industrial Pull UP I2C connection
17.33 €
17.33 €
M-DUINO ETHERNET PLC ARDUINO 42
M-DUINO ETHERNET PLC ARDUINO 42
315.00 €
315.00 €

DALI Bus Power Supply

https://www.industrialshields.com/web/image/product.template/990/image_1920?unique=6bb14fd

120.00 € 120.0 EUR 120.00 €

120.00 €

Not Available For Sale


  • Dali

This combination does not exist.


Are you a company? This is for You! ✅
Details

Reference :
050001000200
Share :

DALI PLC BRIDGE

A maximum of 64 DALI devices connected

DALI PLC Bridge is part of the Connected Lighting product family. This powerful device is used to connected two or more DALI networks over standard mains cabling. Basically, the device couples DALI communication to the mains, and vice versa, which eliminates the need for installation of additional DALI cabling. This determines the DALI PLC Bridge for use is applications where two-wire cabling suitable for DALI is not present, and reconstruction is not planned or possible

KEY FEATURES

  • Support of forward and backward DALI commands according to IEC 62 386-102
  • DALI powered
  • 3-phase support
  • Communication error source detection
  • Dedicated output terminal (mains) for DALI Power Supply
  • Over-voltage protection
  • Reset push button for Network management

TECHNICAL PARAMETERS

  • A maximum of 64 DALI devices with unique addresses can be connected to single network
  • Only one DALI power supply may be used
  • Input parameters: DALI: 12-25 V DC, input current < 20 mA, PLC: 120 / 230 V 


INSTALLATION

For the proper functionality, at least one PLC coupler should be used at the beginning of the network, between the DALI controller and mains, and the another one between the luminaire (or groups of the luminaires) with the DALI driver.

The DALI wiring is not required between the DALI PLC couplers, in the case that the DALI coupler is used in front of the group of the luminaires, they have to be connected with the DALI wires.

INSTALLATION METHOD 1

ONE DALI PLC BRIDGE DEVICE CONNECTED TO ONE OR MORE DALI PLC-IN DEVICES
For the simplest DALI PLC networks, you need only one DALI PLC Bridge that acts as the master connected to several DALI PLC-IN devices. DALI PLC-IN devices are ideal for use where there is no possibility to add additional wiring as they are placed directly within luminaires and only need to be connected to the mains. Perfect for use in heritage buildings such as churches and cultural buildings as well as in places where the construction materials make it overly difficult to install new wiring within the walls and ceilings. It is possible to distribute such networks across one, two, or three phases as required.

INSTALLATION METHOD 2

COUPLING OF ONE OR MORE DALI PLC BRIDGE DEVICES CONNECTED TO DALI BUSES
In some spaces, it may be viable to install DALI buses in some locations but not throughout the entire space. For such cases, DALI PLC is ideal to couple these various DALI buses via the mains wiring into a single network. Each DALI bus requires its own DALI Power Supply and DALI PLC Bridge device to connect it to the rest of the DALI PLC installation. This installation method is useful for spaces ranging from office buildings and hotels to shops and restaurants. It is possible to distribute such networks across one, two, or three phases as required.

INSTALLATION METHOD 3

ONE OR MORE PLC BRIDGE DEVICES CONNECTED TO DALI BUSES COMBINED WITH ONE OR MORE DALI PLC-IN DEVICES
This installation method is very much the same as the previous except that it also includes DALI PLC-IN devices. Such a combination offers the greatest flexibility for positioning and controlling of luminaires within the network and is perfectly suited to use in office buildings, hotels, and even hospitals, where rooms or offices can be equipped with a DALI bus but the corridor requires lighting than runs off the mains. Of course, the principles of the installation method can be applied to almost any type of space. It is possible to distribute such networks across one, two, or three phases as required.

 INSTALLATION METHOD 4

USE OF THREE PHASE WIRING WITH THREE MASTER DALI PLC BRIDGE DEVICES TO CREATE THREE SEPARATE DALI NETWORKS
For larger spaces or complexes like office buildings, factories, supermarkets, and warehouses, 64 DALI devices are simply not enough. Such buildings often use three phase wiring, which opens up the possibility to use each phase as a separate DALI PLC network with 64 DALI devices. Each phase must be used independently of the others in order for this to work and so must have its own DALI controllers and master DALI PLC Bridge device.

A good subtitle

A great way to catch your reader's attention is to tell a story. Everything you consider writing can be told as a story.

Great stories have personality. Consider telling a great story that provides personality. Writing a story with personality for potential clients will assists with making a relationship connection. This shows up in small quirks like word choices or phrases. Write from your point of view, not from someone else's experience.

Great stories are for everyone even when only written for just one person. If you try to write with a wide general audience in mind, your story will ring false and be bland. No one will be interested. Write for one person. If it’s genuine for the one, it’s genuine for the rest.

Dali Yes

Unlock exclusive business pricing

I have read and accept the terms

Thank you for filling the form 👍

Our team will review your data and will come back to you as soon as possible.